בית     To Survive in the Universe    
Services
    Why to Inhabit     Top Contributors     תמונת אסטרו     האוסף     קבוצת דיון     Blog New!     שאלות נפוצות     כניסה  
→ Adopt this star  

HD 139676


תוכן

תמונות

הוסף תמונה שלך

DSS Images   Other Images


מאמרים קשורים

Effective temperature scale and bolometric corrections from 2MASS photometry
We present a method to determine effective temperatures, angularsemi-diameters and bolometric corrections for population I and II FGKtype stars based on V and 2MASS IR photometry. Accurate calibration isaccomplished by using a sample of solar analogues, whose averagetemperature is assumed to be equal to the solar effective temperature of5777 K. By taking into account all possible sources of error we estimateassociated uncertainties to better than 1% in effective temperature andin the range 1.0-2.5% in angular semi-diameter for unreddened stars.Comparison of our new temperatures with other determinations extractedfrom the literature indicates, in general, remarkably good agreement.These results suggest that the effective temperaure scale of FGK starsis currently established with an accuracy better than 0.5%-1%. Theapplication of the method to a sample of 10 999 dwarfs in the Hipparcoscatalogue allows us to define temperature and bolometric correction (Kband) calibrations as a function of (V-K), [m/H] and log g. Bolometriccorrections in the V and K bands as a function of T_eff, [m/H] and log gare also given. We provide effective temperatures, angularsemi-diameters, radii and bolometric corrections in the V and K bandsfor the 10 999 FGK stars in our sample with the correspondinguncertainties.

The infrared void in the Lupus dark clouds revisited: a polarimetric approach
The results of B-band CCD imaging linear polarimetry obtained for starsfrom the Hipparcos catalogue are used to re-examine the distribution ofthe local interstellar medium towards the IRAS 100-μm emission voidin the Lupus dark clouds. The analysis of the obtainedparallax-polarization diagram assigns to the dark cloud Lupus1 adistance between 130 and 150pc and assures the existence of a low columndensity region coincident with the observed infrared void. Moreover,there are clear indications of the existence of absorbing material atdistances closer than 60-100pc, which may be associated with theinterface boundary between the Local Bubble and its neighbourhood LoopIsuperbubble.

On the infrared void in the Lupus dark clouds
Strömgren uvbyβ photometry observations obtained for 205 starsin the general direction of a void in the IRAS 100-μm emission fromthe Lupus dark cloud complex are presented and analysed. The colourexcess versus distance diagram confirms the existence of a regiondepleted from interstellar material, which is also seen in the ROSATsoft X-ray background emission map. The distance to the surroundingmaterial is estimated as being within the interval from 60 to 100pc.This result is in disagreement with previous distance estimates to thesupposed supernova that has been suggested as responsible for clearingthe region from dust. As an alternative, the data presented support thesuggestion that the void may have been produced by the detachment ofmaterial from the interface between LoopI and the Local Bubble as aconsequence of hydromagnetic instabilities. Moreover, the distributionof colour excess as a function of distance supports a value of ~150pc asthe most probable distance to the dark cloud known as Lupus1.

Starlight polarization and CO observations towards the Lupus clouds
We performed an observational study of the dark filaments Lupus 1 andLupus 4 using both polarimetric observations of 190 stars and a sampleof 72 ^12CO profiles towards these clouds. We have estimated lowerlimits to the distances of Lupus 1 and Lupus 4 (>~ 140 and >~ 125pc, respectively). The observational strategy of the survey allows us tocompare the projected magnetic field in an extended area around eachcloud with the magnetic field direction observed to prevail along theclouds. Lupus 4 could have collapsed along the magnetic field lines,while in Lupus 1 the magnetic field appears to be less ordered, havingthe major axis of the filaments parallel to the large-scale projectedmagnetic field. These differences would imply that both filaments havedifferent pattern evolutions. From the CO observations we have probedthe velocity fields of the filaments and the spatial extension of themolecular gas with respect to the dust.

A homogeneous catalog of new UBV and H-beta photometry of B- and A-type stars in and around the Scorpius-Centaurus OB association
B- and A-type stars in and near the Sco-Cen OB association areinvestigated with UBV and H-beta photometry to acquire data relevant tothe luminosity function of Sco-Cen. The measurements generally consistof two 10-s integrations of U, B, V, (W, N) filters, and theobservations are corrected iteratively for atmospheric extinction andinstrumental response. The data presented give the mean V magnitude,mean B-V, mean U-B, and the estimated uncertainties for these values.The catalog provides a homogeneous catalog of data for a large fieldwith stellar objects delineating membership to the association Sco-Cenand that affect the luminosity function of the aggregate.

הכנס מאמר חדש


לינקים קשורים

  • - לא נמצאו לינקים -
הכנס לינק חדש


משמש של הקבוצה הבאה


תצפית ומידע אסטרומטרי

קבוצת-כוכבים:זאב
התרוממות ימנית:15h40m47.16s
סירוב:-35°25'39.6"
גודל גלוי:7.568
מרחק:99.206 פארסק
תנועה נכונה:-86.2
תנועה נכונה:-83.2
B-T magnitude:7.922
V-T magnitude:7.598

קטלוגים וכינוים:
שם עצם פרטי
HD 1989HD 139676
TYCHO-2 2000TYC 7335-29-1
USNO-A2.0USNO-A2 0525-20005815
HIPHIP 76797

→ הזמן עוד קטלוגים וכינוים מוזיר